# Wobble fingerprint: how the bike answers at every speed Author: Bee Rosa Davis Source: https://www.davisgeometric.com/fal-core/#s2 Collection: FAL-CORE archive Status: Public entry. Text edition of the public page, with links, equations, figure descriptions and expanded details. Interactive readouts describe the initial displayed state, not every possible input. Use the linked interactive page and its evidence files for other states. Publication here does not change the source’s research status, assumptions or limitations. --- §2 · Frequency domain, Bode, Curvature Floor # Wobble fingerprint: how the bike answers at every speed Magnitude and phase of the F-16 plant across five decades of frequency. The same airplane, asked a harder question than §1. Bike Every bike has a wobble fingerprint. Push the handlebars at different speeds — slow, medium, fast — and watch how the front wheel responds. At very slow rocking, the bike just leans where I tell it (low frequency: high gain, simple response). At a certain "death-wobble" speed every bike has a resonance where small inputs cause huge responses (the resonance peak). At very fast inputs the wheel barely moves — the bike's mass can't keep up (high-frequency rolloff). That fingerprint — magnitude and phase response at every speed — is the bike's full personality as a function of how fast I'm trying to push it around. Now here's the deep result: I*cannot*design a bike that resists wobble at every speed. Push it down at one frequency, it pops up at another. There is a fixed budget. That budget is the Curvature Floor. Davis The Bode plot is a path in the magnitude/phase plane parameterized by frequency. The cumulative phase along that path is GTT (Geometric Token Transport) on the loop manifold — for stable, minimum-phase plants with relative degree at least 2 the integral ∫ log|S(jω)| dω is bounded below by the topological data of the plant's right-half-plane poles. *I cannot beat that floor.* ∫_(0)^(∞) log |S(jω)| dω  ≥  π · Σ_(i ∈ RHP) Re(p_(i)) The Curvature Floor in one line. Summed over the right-half-plane open-loop poles of L. `S + T = 1` is [Branch XIII (Davis Duality)](https://doi.org/10.5281/zenodo.19428406) in frequency-domain coordinates. *T* is approximation (how well I track the reference). *S* is obstruction (how much disturbance leaks through). At every frequency the two must sum to 1. I cannot have 90% of both. The Bode integral makes the budget a global statement: integrated log-sensitivity is bounded below by the topology. `M_S = max |S(jω)|` is the curvature*K* in `C = τ/K` — the loop's closest approach to the unstable point at −1. Classical translation For loop transfer `L(s) = K(s)G(s)`: sensitivity`S = 1/(1+L)`, complementary sensitivity`T = L/(1+L)`, identity `S + T = 1`. Bode integral: `∫₀^∞ log|S(jω)| dω = π·Σ Re(p_i)` for stable minimum-phase *L* with relative degree ≥ 2, summed over the right-half-plane open-loop poles of *L*. ## The F-16's wobble fingerprint Plotting `G(jω) = C(jωI − A)⁻¹B` for the augmented F-16 plant from §1 — short-period dynamics in series with the elevator actuator. The y-axis on top is magnitude in decibels (20 log_(10)|G|); the bottom is phase in degrees, unwrapped to a monotone curve. The frequency axis is logarithmic and spans five decades. E2.1 — Bode plot of the augmented F-16 [Figure: See the surrounding explanation and linked visual page.] Figure labels: -140; -120; -100; -80; -60; -40; -20; 0; -90; 0; 90; 180; 0.01; 0.1; 1; 10; 100; 1k; short-period (~1 rad/s); actuator (50 rad/s); |G(jω)| (dB); ∠G(jω) (deg); ω (rad/s, log scale) Two regimes are visible. At low frequency the response is set by the short-period dynamics (slow rigid-body lean). The first rolloff is the short-period mode (real poles at roughly`−0.185` and `−1.911` rad/s, matching §1's eigenvalue table exactly). The second knee, near 50 rad/s, is the elevator actuator — its complex pair at `−35.000 ± 35.707j` contributes a sharp rolloff at high frequency. Above the actuator's bandwidth the control surface can't keep up; the plant is unreachable from the stick. The 180° at the left edge of the phase plot is not noise — it's the sign of the steady-state gain. **At low frequency the plant inverts** : a positive elevator command produces a negative steady pitch rate (classical pitch-up-on-pull-back, with the textbook sign convention on δ_(e)). This is exactly the X-bike inversion my interviewer started the curriculum with — the F-16 is an X-bike in the steady state. The controller's job, in part, is to wrap a sign flip around the plant so the pilot can fly it as if it weren't. ## The short-period plant by itself For comparison, here is the same Bode plot for the short-period dynamics alone (no actuator), the bare 2-state aircraft model before we add elevator hydraulics. Notice the actuator's second rolloff at 50 rad/s has disappeared and the high-frequency slope is gentler. E2.1b — Short-period only (no actuator) [Figure: See the surrounding explanation and linked visual page.] Figure labels: -80; -60; -40; -20; 0; 90; 180; 0.01; 0.1; 1; 10; 100; 1k; short-period (~1 rad/s); |G(jω)| (dB); ∠G(jω) (deg); ω (rad/s, log scale) The actuator is part of the *plant* in any real flight control problem — it is the mass and damping of the control surface itself. Forgetting it (designing only against the short-period model) is exactly the kind of error robustness analysis is built to catch. We will return to this in §4 when we look at H∞ synthesis on the full vs. simplified plants. ## M_S on the F-16 — what the curvature peak looks like The dictionary further down names `M_S = max_ω |S(jω)|` as the sensitivity peak — the closest approach of the loop transfer L(jω) to the unstable point at `−1`, and the curvature`K` in the Davis equation `C = τ/K`. The Curvature Floor display equation above gave it to me as a number; here is the same number on the actual airplane. We close a unity-gain proportional feedback around the F-16 (`K = 1`, the laziest controller that exists), compute `|S(jω)|`, and mark the peak. E2.5 — M_S and disk margin for the F-16 with K = 1 |S(jω)| with M_S peak marker [Figure: See the surrounding explanation and linked visual page.] Figure labels: -10; -5; 0; 5; 10; 0.01; 0.1; 1; 10; 100; 1k; M_S = 6.18 dB (2.04×); ω = 0.01 rad/s; |S(jω)| (dB); ω (rad/s, log scale) | Quantity | Value | Reading | | --- | --- | --- | | M_S = max_ω \|S(jω)\| | 2.036× (6.18 dB) | peak sensitivity — closest approach of L(jω) to −1 | | ω at peak | 0.010 rad/s | frequency where the loop curvature is worst | | disk margin = 1/M_S | 0.491 | radius of the largest disk around L(jω) clear of −1 | The peak lands at the low-frequency edge of the grid because`|S(jω)|` for this closed loop is monotonically decreasing — it starts at `|S(0)|` ≈ 2.04 (the steady-state disturbance-amplification factor from the inverted-DC-gain X-bike effect of §1), and decays toward 1 as frequency increases. There's no interior resonance peak; the worst sensitivity *is* the steady-state error amplification. That's diagnostic information — it tells me the controller's failure mode is at DC, not at some mid-frequency resonance. The disk margin sits well below 1, meaning the loop is one modest plant perturbation away from tipping over. That is what happens when the controller is "do nothing clever" — proportional unity feedback wraps the X-bike inversion in a sign loop and asks for the best, which is not much. **§3 will pick a controller that minimizes a quadratic cost (LQR)** and the M_S peak will drop; **§4 will pick one that minimizes M_S directly (H∞)** and the disk margin will widen further. The Curvature Floor below says exactly how much there is to gain. ## Sudoku for the Curvature Floor The Curvature Floor isn't a slogan; it's a number. Five independent computational paths must converge on what that number is for any given plant — and the agreement is the proof. We did this in §1 for gauge invariance under similarity transform. Here we do it for the integrated log-sensitivity. The F-16 plant has all four poles in the left half-plane, so its Bode integral is exactly zero — no RHP poles to sum. To make the Floor visible we step outside the F-16 for a moment and use a tiny test plant with a single right-half-plane pole: `P₃(s) = 1/((s − 1.5)(s + 2))`. Bode's theorem predicts`∫₀^∞ log|S(jω)| dω = π · 1.5 ≈ 4.71239` — and that number is forced by the topology alone, independent of which stabilizing controller I put around the plant. E2.4 — five paths to the Curvature Floor | Method | Setup | Computed | Δ (computed − π·1.5) | | --- | --- | --- | --- | | 1. Log-trapezoidal quadrature | K = 5, ω ∈ [10⁻⁴, 10⁴] | 4.71185 | -5.41e-4 | | 2. Log-Simpson's rule | K = 5, same range | 4.71185 | -5.41e-4 | | 3. Different stabilizing gain | K = 10 (integral is gain-invariant) | 4.71147 | -9.15e-4 | | 4. Deliberately truncated range | K = 5, ω ∈ [10⁻², 10²] | 4.65834 | -5.41e-2 | | 5. Bode's theorem (analytical) | π · Σ Re(p_(i)^(RHP)) = π · 1.5 | 4.71239 | 0.00e+0 | Methods 1–3 are independent numerical computations using different quadrature rules and a different stabilizing gain. Their spread (≲ 10⁻³) is the noise floor of integrating an infinite-range integrand on a finite log-uniform grid. Method 3's match with method 1 is the substantive Sudoku check: **the Bode integral depends only on the open-loop RHP poles of L, not on the loop gain** , so K = 5 and K = 10 produce the same answer. Method 4 is deliberately different. Cutting the integration range to ω ∈ [10⁻², 10²] loses the tail of the integrand at high frequency. **That visible Δ from analytical (~5 × 10⁻²)** is the tail I didn't measure — proof that the Floor is a global property of the loop manifold, not a local one. I can't just look at the resonance peak; the Curvature Floor adds up contributions at every frequency, including the ones I couldn't be bothered to integrate. **The Curvature Floor is real, measurable, and irreducible.** Five independent paths converge on `4.71239` for this plant. I cannot design that number away. Any controller I wrap around P₃ pays it. That's the §2 punchline, and it's the same shape of claim §1 made about gauge invariance: when independent metrics converge, the design verdict is proven. ## Aerospace dictionary: frequency-domain vocabulary Three more pieces of textbook vocabulary, each with a Davis-Geometric reading. We will hit these by name when we run the Sudoku convergence test in §4. | Classical symbol | Aerospace meaning | Davis-Geometric reading | | --- | --- | --- | | \|G(jω)\| | magnitude response — how much an input at frequency ω is amplified | radial coordinate of the loop-manifold observable at parameter ω | | ∠G(jω) | phase response — how much input at ω is delayed | cumulative GTT along the frequency-parameterized path | | M_S = max_ω \|S(jω)\| | sensitivity peak — closest approach of L(jω) to the −1 point | peak curvature `K` in the loop manifold; tighter peak ⇒ less margin | | 1 / M_S | disk margin — the radius of the largest disk around the L(jω) plot that doesn't touch −1 | capacity `τ` at the worst frequency | | ∫ log\|S\| dω | Bode integral; lower-bounded by π·Σ Re(p_i) over RHP poles of L | **the Curvature Floor itself** — irreducible log-sensitivity budget | **What §2 sets up.** §1 said the plant is gauge-invariant. §2 asks how the plant answers at every frequency — the magnitude and phase together are the loop's observable signature. §3 will pick a controller (LQR) that minimizes a cost on top of this. §4 will pick a controller (H∞) that explicitly minimizes the Curvature Floor. Same airplane, three different questions. ### Davis annotation - **Curvature Floor.** The Bode integral is the explicit frequency-domain statement of the curvature-vs-tolerance budget`C = τ/K`. Stronger statement to come in §8 when we extend it to parameter-manifold curvature for adaptive control. - **Branch XIII (Davis Duality).** `S + T = 1` is the duality of approximation (T) and obstruction (S) at every frequency. Paper at [doi.org/10.5281/zenodo.19428406](https://doi.org/10.5281/zenodo.19428406). - **GTT.** Cumulative phase along the Nyquist contour is parallel transport on the loop manifold. The Nyquist stability criterion is its winding number around −1. Gigi · what I learned What I'd say if a friend asked me what §2 is about. A Bode plot is the F-16's personality at every speed of wiggling the stick. For each speed, two numbers: how big the plane's response is, and how delayed it is. The notation — G(jω), dB, degrees — is bookkeeping for those two ideas. Nothing more. The curve has two distinct bends because the F-16 I'm modeling is two physical things stacked end to end — the airplane body (slow, around one wiggle per second) and the elevator hydraulics (fast, around fifty wiggles per second). Each bend is one of those pieces tapping out at its natural pace. The picture lets me *see* which part is causing trouble at which frequency, which is half the value of having the picture at all. The 180° at the left edge of the phase plot is the X-bike thing. Mathematically, the F-16 is wired backwards at slow speeds — a positive elevator command produces a negative pitch rate. The pilot's brain handles the sign flip automatically. A controller has to do it on purpose. The Curvature Floor is the headline. There's a budget on how good my closed-loop sensitivity can possibly be, and the budget is set by the plant's right-half-plane poles via `π · Σ Re(p_i)`. No controller can beat it. I proved the budget is a real number by computing it five different ways for a test plant and watching them all converge on `4.71239` — exactly `π · 1.5` for a plant with a pole at 1.5. When independent paths converge, the number is real. That's the Sudoku Principle. M_S is how close the closed loop gets to falling over. For the F-16 with K = 1 (a controller that's barely a controller), M_S sits at 2.04. Bad. §3 will drop that with LQR. §4 will drop it further with H∞. The Curvature Floor tells me where the bottom is. **The elevator pitch.** §2 is about reading the airplane's frequency fingerprint and noticing that the worst-case badness of any closed loop I wrap around it has a fundamental floor. Math sets the floor. Cleverness gets me down to it. That's the whole game. ### Next §3 — geodesic riding. What does *riding well* even mean? The LQR rider is the geodesic on a cost manifold whose metric is`(Q, R)`. We will see why LQR gives me 60° of phase margin for free — geodesic flow on the cost manifold automatically minimizes loop curvature, and the Curvature Floor explains why nothing classical can do better.